How to use push monitoring via HTTP
Using push monitoring via HTTP with PRTG: Step-by-Step Guide

- Use cases for HTTP push monitoring
- PRTG sensors for HTTP push monitoring
- How to set up HTTP push monitoring
- Configure an external device to point to PRTG
Push monitoring via HTTP means to monitor data that a device automatically sends to PRTG with the help of different HTTP Push sensors. For push monitoring, webhooks are used to push messages from devices with specifically configured callbacks to PRTG using HTTP. Webhooks are actions triggered by an event that send the requested information to a specific URL in real time.
Use cases for HTTP push monitoring
The push technology can be useful in different cases:
- The target device does not allow requests via the usual technologies, for example, SSH or SNMP.
- You want to monitor web servers that can periodically run specific scripts or PHP.
- You want to monitor Linux services. For more information, see the Knowledge Base: How can I monitor and automatically restart a service on a Linux host?
- You want to migrate many EXE sensors into one EXE script that manages the HTTP Push sensors and sends data to them. For more information, see the Knowledge Base: How can I monitor SCVMM hosts and VMs with PRTG?
- You want to monitor data sent by IoT devices like Sigfox sensors. For more information, see the Knowledge Base: How can I monitor Sigfox callbacks with PRTG? and How can I monitor Sigfox geolocation with PRTG?
Bring your monitoring experience to the next level with PRTG
Get full visibility with real-time dashboards, alerts, and customizable sensors
PRTG sensors for HTTP push monitoring
HTTP Push Count
The HTTP Push Count sensor counts received messages that are pushed via an HTTP request to PRTG. It can show the following:
- Downtime
- Number of messages received

HTTP Push Data
The HTTP Push Data sensor displays numeric values from received messages that are pushed via an HTTP request to PRTG. It can show the following:
- Downtime
- Received value and an optional message in one channel

HTTP Push Data Advanced
The HTTP Push Data Advanced sensor displays data from received messages that are pushed via an HTTP request to PRTG. It can show the following:
- Number values from received push messages
- Complete messages themselves in valid XML or JSON format

HTTP IoT Push Data Advanced
The HTTP IoT Push Data Advanced sensor displays data from messages that are received from Internet of Things (IoT) capable devices and that are pushed via an HTTPS request to PRTG. It can show the following:
- Downtime
- Data received from the message encoded in valid XML or JSON in several channels

How to set up HTTP push monitoring
Add an HTTP Push sensor in PRTG
-
Create a new device or use an existing device with the IP address of your probe system, for example, the probe device, or with the DNS name of your PRTG Hosted Monitor instance.
-
Add an HTTP Push sensor to the new device or the probe device: right-click the respective device and select Add Sensor from the context menu. Then filter for Push Message Receiver under Technology Used?.
-
Click the sensor that you want to add. Choose between the HTTP Push Data sensor, the HTTP Push Count sensor, the HTTP Push Data Advanced sensor, or the HTTP IoT Push Data Advanced sensor.

4. In section HTTP Push , define the following settings:
- Select the security of the HTTP requests. You can choose between HTTP (unsecure) and HTTPS (secured with TLS 1.2 only).
Note : The sensor HTTP IoT Push Data Advanced can only use HTTPS. - Enter the Port on which the sensor listens for HTTP requests. The default port is 5050 for HTTP and 5051 for HTTPS.
- Choose the HTTP Request Method of the webhook. This can be ANY , GET , or POST.
Note : The request method POST sends the XML or JSON encoded HTTP body as POST data. For POST requests, use an HTTP content type other than application/x-www-form-urlencoded. We strongly recommend that you use the HTTP content types application/xml or application/json. - The Identification Token is the token that PRTG uses to find the matching sensor for an incoming push message. When you create the sensor, this token is {_guid}. PRTG replaces this value with an automatically generated token. You can also enter a custom identification token, if required.
_Note : The Identification Token setting for the sensor HTTP IoT Push Data Advanced can be found in section HTTP Push Authentication. - For the sensor HTTP Push Data, you also need to define the Value Type of the data that the external device sends. Choose between Integer , Float , or Counter. This setting can be found in section HTTP Push Data.


PRTG makes monitoring as easy as it gets
Custom alerts and data visualization let you quickly identify and prevent all kinds of issues
Configure an external device to point to PRTG
To enable an external device to send push messages to the intended HTTP Push sensor in PRTG,
you need to provide the device with the URL that points to the according sensor.
HTTP Push Count sensor
The HTTP Push Count sensor can be reached via the following URL:
http:// <probe_ip_address>:<port_number>/<identification_token>
Replace the parameters with the following values:
- The < probe_ip_address> is the IP address of the probe system that runs the sensor. For PRTG Hosted Monitor, it is the DNS name of the respective instance.
- The < port_number> is the port that you entered during the sensor setup. You can find the port number in the sensor settings.
- The < identification_token> is the value that you defined during the sensor setup or the default value that PRTG automatically created. You can find the identification token in the sensor settings.
Example URL: http://127.0.0.1:5050/XYZ-123
A correctly configured sensor that receives push data can look like this
A correctly configured sensor that receives push data can look like this
HTTP Push Data sensor
The HTTP Push Data sensor can be reached via the following URL:
http:// <probe_ip_address>:<port_number>/<identification_token>?value=<integer_or_float>&text=<text_message>
Replace the parameters with the following values:
- The < probe_ip_address> is the IP address of the probe system that runs the sensor. For PRTG Hosted Monitor, it is the DNS name of the respective instance.
- The < port_number> is the port that you entered during the sensor setup. You can find the port number in the sensor settings.
- The < identification_token> is the value that you defined during sensor setup or the default value that PRTG automatically created. You can find the identification token in the sensor settings.
- The ?value parameter can be an < integer_or_float> depending on the data that your external device sends. The value that you enter here must match the value type that you specified in the sensor settings.
- The ?text parameter is optional: you can also leave it out. For < text_message>, you can add a custom text that PRTG shows as the sensor message. The text message must be URL encoded.
Example URL: http://127.0.0.1:5050/XYZ-123 value=0 &text=this%20is%20a%20sensor%20message
A correctly configured sensor that receives push data can look like this
A correctly configured sensor that receives push data can look like this
HTTP Push Data Advanced and HTTP IoT Push Data Advanced sensor
The HTTP Push Data and HTTP IoT Push Data Advanced sensors can be reached via the following URLs, depending on the type of HTTP request:
- GET request:
http:// <probe_ip_address>:<port_number>/<identification_token>?content=<valid_XML_or_JSON> - POST request:
http:// <probe_ip_address>:<port_number>/<identification_token>
Replace the parameters with the following values:
- The < probe_ip_address> is the IP address of the probe system that runs the sensor. For PRTG Hosted Monitor, it is the DNS name of the respective instance.
- The < port_number> is the port that you entered during the sensor setup. You can find the port number in the sensor settings.
Note : For the HTTP IoT Push Data Advanced sensor, the port is always 5051. It cannot be changed. - The < identification_token> is the value that you defined during sensor setup or the default value that PRTG automatically created. You can find the identification token in the sensor settings.
- The ?content parameter for GET requests must be < valid_XML_or_JSON> and has to match the format as defined in the PRTG Manual: Custom Sensors. The content specifies custom channels and optional text messages that PRTG shows as the sensor message. The text message must be URL encoded.
Minimum example URL for a GET request:
http://127.0.01:5050/XYZ-123?content= <prtg><result><channel>MyChannel</channel><value>10</value></result><text>this%20is%20a%20sensor%20message</text></prtg>
Note : By default, values within the < value> tags must be integers. If your external device returns float values, you must explicitly define this value type with < float> tags. Otherwise, the sensor shows 0 values in the respective channels.
Example:
http://127.0.01:5050/XYZ-123?content= <prtg><result><channel>MyChannel</channel><value>10.45</value><float>1</float></result><text>this%20is%20a%20sensor%20message</text></prtg>
A correctly configured sensor that receives push data can look like this
A correctly configured sensor that receives push data can look like this
This how-to guide only scratches the surface?
Get more deep-dive information here!

Video: PRTG & Sigfox

Knowledge Base: Monitoring IoT and IIoT environments with Node-RED