5.14 SEQUENCE (GENERATOR)
A sequence — or generator — is a database object used to get unique number values to fill a series. Sequence is the SQL-compliant term for the same thing which — in Firebird — has traditionally been known as generator. Firebird has syntax for both terms.
Sequences are always stored as 64-bit integers, regardless of the SQL dialect of the database.
Caution
If a client is connected using Dialect 1, the server handles sequence values as 32-bit integers. Passing a sequence value to a 32-bit field or variable will not cause errors as long as the current value of the sequence does not exceed the limits of a 32-bit number. However, as soon as the sequence value exceeds this limit, a database in Dialect 3 will produce an error. A database in Dialect 1 will truncate (overflow) the value, which could compromise the uniqueness of the series.
This section describes how to create, alter, set and drop sequences.
5.14.1 CREATE SEQUENCE
Used forCreating a new SEQUENCE (GENERATOR)
Available inDSQL, ESQL
Syntax
1. CREATE {SEQUENCE | GENERATOR} seq_name
2. [START WITH start_value]
3. [INCREMENT [BY] increment]
Table 5.14.1.1 CREATE SEQUENCE Statement Parameters
| Parameter | Description |
|---|---|
| seq_name | Sequence (generator) name. The maximum length is 63 characters |
| start_value | Initial value of the sequence. Default is 1. |
| increment | Increment of the sequence (when using NEXT VALUE FOR seq_name); cannot be 0. Default is 1. |
The statements CREATE SEQUENCE and CREATE GENERATOR are synonymous — both create a new sequence. Either can be used, but CREATE SEQUENCE is recommended as that is the syntax defined in the SQL standard.
When a sequence is created, its current value is set so that the next value obtained from NEXT VALUE FOR *seq_name* is equal to start_value. In other words, the current value of the sequence is set to (*start_value* - *increment*). By default, the start_value is 1 (one).
The optional INCREMENT [BY] clause allows you to specify an increment for the NEXT VALUE FOR seq_name expression. By default, the increment is 1 (one). The increment cannot be set to 0 (zero). The GEN_ID(seq_name, <step>) function can be called instead, to step the series by a different integer number. The increment specified through INCREMENT [BY] is not used for GEN_ID.
Non-standard behaviour for negative increments
The SQL standard specifies that sequences with a negative increment should start at the maximum value of the sequence (263 - 1) and count down. Firebird does not do that, and instead starts at 1.
This may change in a future Firebird version.
5.14.1.1 Who Can Create a Sequence?
The CREATE SEQUENCE (CREATE GENERATOR) statement can be executed by:
- Administrators
- Users with the
CREATE SEQUENCE(CREATE GENERATOR) privilege
The user executing the CREATE SEQUENCE (CREATE GENERATOR) statement becomes its owner.
5.14.1.2 Examples of CREATE SEQUENCE
- Creating the
EMP_NO_GENsequence usingCREATE SEQUENCE.
1. CREATE SEQUENCE EMP_NO_GEN;
2. Creating the EMP_NO_GEN sequence using CREATE GENERATOR.
1. CREATE GENERATOR EMP_NO_GEN;
3. Creating the EMP_NO_GEN sequence with an initial value of 5 and an increment of 1.
1. CREATE SEQUENCE EMP_NO_GEN START WITH 5;
4. Creating the EMP_NO_GEN sequence with an initial value of 1 and an increment of 10.
1. CREATE SEQUENCE EMP_NO_GEN INCREMENT BY 10;
5. Creating the EMP_NO_GEN sequence with an initial value of 5 and an increment of 10.
1. CREATE SEQUENCE EMP_NO_GEN START WITH 5 INCREMENT BY 10;
See alsoSection 5.14.2, ALTER SEQUENCE, Section 5.14.3, CREATE OR ALTER SEQUENCE, Section 5.14.4, DROP SEQUENCE, Section 5.14.5, RECREATE SEQUENCE, Section 5.14.6, SET GENERATOR, NEXT VALUE FOR, GEN_ID() function
5.14.2 ALTER SEQUENCE
Used forSetting the next value of a sequence or changing its increment
Available inDSQL
Syntax
1. ALTER {SEQUENCE | GENERATOR} seq_name
2. [RESTART [WITH newvalue]]
3. [INCREMENT [BY] increment]
Table 5.14.2.1 ALTER SEQUENCE Statement Parameters
| Parameter | Description |
|---|---|
| seq_name | Sequence (generator) name |
| newvalue | New sequence (generator) value. A 64-bit integer from -2-63 to 263-1. |
| increment | Increment of the sequence (when using NEXT VALUE FOR seq_name); cannot be 0. |
The ALTER SEQUENCE statement sets the current value of a sequence to the specified value and/or changes the increment of the sequence.
The RESTART WITH *newvalue* clause allows you to set the next value generated by NEXT VALUE FOR *seq_name*. To achieve this, the current value of the sequence is set to (*newvalue* - *increment*) with increment either as specified in the statement, or stored in the metadata of the sequence. The RESTART clause (without WITH) restarts the sequence with the initial value stored in the metadata of the sequence.
Note
Contrary to Firebird 3.0, in Firebird 4.0 RESTART WITH *newvalue* only restarts the sequence with the specified value, and does not store newvalue as the new initial value of the sequence. A subsequent ALTER SEQUENCE RESTART will use the initial value specified when the sequence was created, and not the newvalue of this statement. This behaviour is specified in the SQL standard.
It is currently not possible to change the initial value stored in the metadata.
Warning
Incorrect use of the ALTER SEQUENCE statement (changing the current value of the sequence or generator) is likely to break the logical integrity of data, or result in primary key or unique constraint violations.
INCREMENT [BY] allows you to change the sequence increment for the NEXT VALUE FOR expression.
Note
Changing the increment value takes effect for all queries that run after the transaction commits. Procedures that are called for the first time after changing the commit, will use the new value if they use NEXT VALUE FOR. Procedures that were already used (and cached in the metadata cache) will continue to use the old increment. You may need to close all connections to the database for the metadata cache to clear, and the new increment to be used. Procedures using NEXT VALUE FOR do not need to be recompiled to see the new increment. Procedures using GEN_ID(gen, expression) are not affected when the increment is changed.
5.14.2.1 Who Can Alter a Sequence?
The ALTER SEQUENCE (ALTER GENERATOR) statement can be executed by:
- Administrators
- The owner of the sequence
- Users with the
ALTER ANY SEQUENCE(ALTER ANY GENERATOR) privilege
5.14.2.2 Examples of ALTER SEQUENCE
- Setting the value of the
EMP_NO_GENsequence so the next value is 145.
1. ALTER SEQUENCE EMP_NO_GEN RESTART WITH 145;
2. Resetting the base value of the sequence EMP_NO_GEN to the initial value stored in the metadata
1. ALTER SEQUENCE EMP_NO_GEN RESTART;
3. Changing the increment of sequence EMP_NO_GEN to 10
1. ALTER SEQUENCE EMP_NO_GEN INCREMENT BY 10;
See alsoSection 5.14.6, SET GENERATOR, Section 5.14.1, CREATE SEQUENCE, Section 5.14.3, CREATE OR ALTER SEQUENCE, Section 5.14.4, DROP SEQUENCE, Section 5.14.5, RECREATE SEQUENCE, NEXT VALUE FOR, GEN_ID() function
5.14.3 CREATE OR ALTER SEQUENCE
Used forCreating a new or modifying an existing sequence
Available inDSQL, ESQL
Syntax
1. CREATE OR ALTER {SEQUENCE | GENERATOR} seq_name
2. {RESTART | START WITH start_value}
3. [INCREMENT [BY] increment]
Table 5.14.3.1 CREATE OR ALTER SEQUENCE Statement Parameters
| Parameter | Description |
|---|---|
| seq_name | Sequence (generator) name. The maximum length is 63 characters |
| start_value | Initial value of the sequence. Default is 1. |
| increment | Increment of the sequence (when using NEXT VALUE FOR seq_name); cannot be 0. Default is 1. |
If the sequence does not exist, it will be created. An existing sequence will be changed:
- If
RESTARTis specified, the sequence will restarted with the initial value stored in the metadata - If the
START WITHclause is specified, the sequence is restarted with start_value, but the start_value is not stored. In other words, it behaves asRESTART WITHin Section 5.14.2, ALTER SEQUENCE. - If the
INCREMENT [BY]clause is specified, increment is stored as the increment in the metadata, and used for subsequent calls toNEXT VALUE FOR
5.14.3.1 Example of CREATE OR ALTER SEQUENCE
Create a new or modify an existing sequence EMP_NO_GEN
1. CREATE OR ALTER SEQUENCE EMP_NO_GEN
2. START WITH 10
3. INCREMENT BY 1
See alsoSection 5.14.1, CREATE SEQUENCE, Section 5.14.2, ALTER SEQUENCE, Section 5.14.4, DROP SEQUENCE, Section 5.14.5, RECREATE SEQUENCE, Section 5.14.6, SET GENERATOR, NEXT VALUE FOR, GEN_ID() function
5.14.4 DROP SEQUENCE
Used forDropping (deleting) a SEQUENCE (GENERATOR)
Available inDSQL, ESQL
Syntax
1. DROP {SEQUENCE | GENERATOR} seq_name
Table 5.14.4.1 DROP SEQUENCE Statement Parameter
| Parameter | Description |
|---|---|
| seq_name | Sequence (generator) name. The maximum length is 63 characters |
The statements DROP SEQUENCE and DROP GENERATOR statements are equivalent: both drop (delete) an existing sequence (generator). Either is valid but DROP SEQUENCE, being defined in the SQL standard, is recommended.
The statements will fail if the sequence (generator) has dependencies.
5.14.4.1 Who Can Drop a Sequence?
The DROP SEQUENCE (DROP GENERATOR) statement can be executed by:
- Administrators
- The owner of the sequence
- Users with the
DROP ANY SEQUENCE(DROP ANY GENERATOR) privilege
5.14.4.2 Example of DROP SEQUENCE
Dropping the EMP_NO_GEN series:
1. DROP SEQUENCE EMP_NO_GEN;
See alsoSection 5.14.1, CREATE SEQUENCE, Section 5.14.3, CREATE OR ALTER SEQUENCE, Section 5.14.5, RECREATE SEQUENCE
5.14.5 RECREATE SEQUENCE
Used forCreating or recreating a sequence (generator)
Available inDSQL, ESQL
Syntax
1. RECREATE {SEQUENCE | GENERATOR} seq_name
2. [START WITH start_value]
3. [INCREMENT [BY] increment]
Table 5.14.5.1 RECREATE SEQUENCE Statement Parameters
| Parameter | Description |
|---|---|
| seq_name | Sequence (generator) name. The maximum length is 63 characters |
| start_value | Initial value of the sequence |
| increment | Increment of the sequence (when using NEXT VALUE FOR seq_name); cannot be 0 |
See Section 5.14.1, CREATE SEQUENCE for the full syntax of CREATE SEQUENCE and descriptions of defining a sequences and its options.
RECREATE SEQUENCE creates or recreates a sequence. If a sequence with this name already exists, the RECREATE SEQUENCE statement will try to drop it and create a new one. Existing dependencies will prevent the statement from executing.
5.14.5.1 Example of RECREATE SEQUENCE
Recreating sequence EMP_NO_GEN
1. RECREATE SEQUENCE EMP_NO_GEN
2. START WITH 10
3. INCREMENT BY 2;
See alsoSection 5.14.1, CREATE SEQUENCE, Section 5.14.2, ALTER SEQUENCE, Section 5.14.3, CREATE OR ALTER SEQUENCE, Section 5.14.4, DROP SEQUENCE, Section 5.14.6, SET GENERATOR, NEXT VALUE FOR, GEN_ID() function
5.14.6 SET GENERATOR
Used forSetting the current value of a sequence or generator to a specified value
Available inDSQL, ESQL
Syntax
1. SET GENERATOR seq_name TO new_val
Table 5.14.6.1 SET GENERATOR Statement Parameters
| Parameter | Description |
|---|---|
| seq_name | Generator (sequence) name |
| new_val | New sequence (generator) value. A 64-bit integer from -2-63 to 263-1. |
The SET GENERATOR statement sets the current value of a sequence or generator to the specified value.
Note
Although SET GENERATOR is considered outdated, it is retained for backward compatibility. Use of the standards-compliant ALTER SEQUENCE is recommended.
5.14.6.1 Who Can Use a SET GENERATOR?
The SET GENERATOR statement can be executed by:
- Administrators
- The owner of the sequence (generator)
- Users with the
ALTER ANY SEQUENCE(ALTER ANY GENERATOR) privilege
5.14.6.2 Example of SET GENERATOR
Setting the value of the EMP_NO_GEN sequence to 145:
1. SET GENERATOR EMP_NO_GEN TO 145;
Note
Similar effects can be achieved with Section 5.14.2, ALTER SEQUENCE:
1. ALTER SEQUENCE EMP_NO_GEN
2. RESTART WITH 145 + increment;
Here, the value of increment is the current increment of the sequence. We need add it as ALTER SEQUENCE calculates the current value to set based on the next value it should produce.
See alsoSection 5.14.2, ALTER SEQUENCE, Section 5.14.1, CREATE SEQUENCE, Section 5.14.3, CREATE OR ALTER SEQUENCE, Section 5.14.4, DROP SEQUENCE, NEXT VALUE FOR, GEN_ID() function