Chapter 3. Data Types and Subtypes
Data of various types are used to:
- define columns in a database table in the
CREATE TABLEstatement or change columns usingALTER TABLE - declare or change a domain using the
CREATE DOMAINorALTER DOMAINstatements - declare local variables in stored procedures, PSQL blocks and triggers and specify parameters in stored procedures
- indirectly specify arguments and return values when declaring external functions (UDFs — user-defined functions)
- provide arguments for the
CAST()function when explicitly converting data from one type to another
Table 3.1 Overview of Data Types
| Name | Size | Precision & Limits | Description |
|---|---|---|---|
BIGINT |
64 bits | From -263 to (263 - 1) | Signed 64-bit integer. This data type is available in Dialect 3 only |
BINARY(n) |
n bytes | from 1 to 32,767 bytes | A fixed-length binary data type; synonym for CHAR(n) CHARACTER SET OCTETS Values shorter than the declared length are padded with NUL up to the declared length. If the number of characters is not specified, 1 is used by default. |
BLOB |
Varying | The size of a BLOB segment is limited to 64K. The maximum size of a BLOB field is 4 GB |
A data type of variable size for storing large amounts of data, such as images, text, digital sounds. The basic structural unit is a segment. The blob subtype defines its content |
BOOLEAN |
8 bits | false, true, unknown | Boolean data type |
CHAR(n), CHARACTER(n) |
n characters. Size in bytes depends on the encoding, the number of bytes in a character | from 1 to 32,767 bytes | A fixed-length character data type. Values shorter than the declared length are padded with spaces (NUL for character set OCTETS) up to the declared length. If the number of characters is not specified, 1 is used by default. |
DATE |
32 bits | From 0001-01-01 AD to 9999-12-31 AD | Date only, no time element |
DECFLOAT (dec_prec) |
64 bits or 128 bits | dec_prec = 16 or 34, defines the number of decimal digits | Decimal floating-point type |
DECIMAL (precision, scale) |
Varying (16, 32, 64 or 128 bits) | precision = from 1 to 38, defines the least possible number of digits to store; scale = from 0 to 38, defines the number of digits after the decimal point | A number with a decimal point that has scale digits after the point. scale must be less than or equal to precision. Example: DECIMAL(10,3) contains a number in exactly the following format: ppppppp.sss |
DOUBLE PRECISION |
64 bits | 2.225 10-308 to 1.797 10308 | Double-precision IEEE, ~15 digits, reliable size depends on the platform |
FLOAT |
32 bits | 1.175 10-38 to 3.402 1038 | Single-precision IEEE, ~7 digits |
FLOAT (bin_prec) |
32 bits or 64 bits | bin_prec binary precision | Binary precision 1 - 24: synonym for FLOAT (32-bit single precision) 25 - 53: synonym for DOUBLE PRECISION (64-bit double precision) |
INTEGER, INT |
32 bits | -2,147,483,648 up to 2,147,483,647 | Signed 32-bit integer |
INT128 |
128 bits | From -2127 to (2127 - 1) | Signed 128-bit integer |
NUMERIC (precision, scale) |
Varying (16, 32, 64 or 128 bits) | precision = from 1 to 38, defines the exact number of digits to store; scale = from 0 to 38, defines the number of digits after the decimal point | A number with a decimal point that has scale digits after the point. scale must be less than or equal to precision. Example: NUMERIC(10,3) contains a number in exactly the following format: ppppppp.sss |
REAL |
32-bits | Synonym for FLOAT |
|
SMALLINT |
16 bits | -32,768 to 32,767 | Signed short (word) |
TIME [WITHOUT TIME ZONE] |
4 bytes | 0:00 to 23:59:59.9999 | Time of day. It cannot be used to store an interval of time. |
TIME WITH TIME ZONE |
6 bytes | 0:00 to 23:59:59.9999 | Time of day with either a time zone offset or named zone. It cannot be used to store an interval of time. |
TIMESTAMP [WITHOUT TIME ZONE] |
8 bytes | From start of day 0001-01-01 AD to end of day 9999-12-31 AD | Date and time of day |
TIMESTAMP WITH TIME ZONE |
10 bytes | From start of day 0001-01-01 AD to end of day 9999-12-31 AD | Date and time of day with either a time zone offset or named zone. |
VARBINARY(n), BINARY VARYING(n) |
n bytes | from 1 to 32,765 bytes | Variable length string type; synonym for VARCHAR(n) CHARACTER SET OCTETS. The total size cannot be larger than (32KB-3). The two leading bytes store the declared length. There is no default size: the n argument is mandatory. Leading and trailing NUL characters are stored, and they are not trimmed, except for those trailing characters that are past the declared length. |
VARCHAR(n), CHAR VARYING(n), CHARACTER VARYING(n) |
n characters. Size in bytes depends on the encoding, the number of bytes in a character | from 1 to 32,765 bytes | Variable length string type. The total size of characters in bytes cannot be larger than (32KB-3), taking into account their encoding. The two leading bytes store the declared length. There is no default size: the n argument is mandatory. Leading and trailing spaces are stored, and they are not trimmed, except for those trailing characters that are past the declared length. |
Note About Dates
Bear in mind that a time series consisting of dates in past centuries is processed without taking into account the actual historical facts, as though the Gregorian calendar were applicable throughout the entire series.
3.1 Integer Data Types
The SMALLINT, INTEGER, BIGINT and INT128 data types are used for integers of various precision in Dialect 3. Firebird does not support an unsigned integer data type.
3.1.1 SMALLINT
The 16-bit SMALLINT data type is for compact data storage of integer data for which only a narrow range of possible values is required. Numbers of the SMALLINT type are within the range from -216 to 216 - 1, that is, from -32,768 to 32,767.
SMALLINT Examples
1. CREATE DOMAIN DFLAG AS SMALLINT DEFAULT 0 NOT NULL
2. CHECK (VALUE=-1 OR VALUE=0 OR VALUE=1);
4. CREATE DOMAIN RGB_VALUE AS SMALLINT;
3.1.2 INTEGER
The INTEGER data type is a 32-bit integer. The shorthand name of the data type is INT. Numbers of the INTEGER type are within the range from -232 to 232 - 1, that is, from -2,147,483,648 to 2,147,483,647.
INTEGER Example
1. CREATE TABLE CUSTOMER (
2. CUST_NO INTEGER NOT NULL,
3. CUSTOMER VARCHAR(25) NOT NULL,
4. CONTACT_FIRST VARCHAR(15),
5. CONTACT_LAST VARCHAR(20),
6. ...
7. PRIMARY KEY (CUST_NO) )
3.1.3 BIGINT
BIGINT is an SQL:99-compliant 64-bit integer data type, available only in Dialect 3. If a client uses Dialect 1, the generator value sent by the server is reduced to a 32-bit integer (INTEGER). When Dialect 3 is used for connection, the generator value is of type BIGINT.
Numbers of the BIGINT type are within the range from -263 to 263 - 1, or from -9,223,372,036,854,775,808 to 9,223,372,036,854,775,807.
3.1.4 INT128
INT128 is a 128-bit integer data type. This type is not defined in the SQL standard.
Numbers of the INT128 type are within the range from -2127 to 2127 - 1.
3.1.5 Hexadecimal Format for Integer Numbers
Starting from Firebird 2.5, constants of integer types can be specified in a hexadecimal format by means of 9 to 16 hexadecimal digits for BIGINT or 1 to 8 digits for INTEGER. Hex representation for writing to SMALLINT is not explicitly supported, but Firebird will transparently convert a hex number to SMALLINT if necessary, provided it falls within the ranges of negative and positive SMALLINT.
Note
The hexadecimal integer literals currently do not support INT128 values.
See <https://github.com/FirebirdSQL/firebird/issues/6809>
The usage and numerical value ranges of hexadecimal notation are described in more detail in the discussion of number constants in the chapter entitled Common Language Elements.
Examples Using Integer Types
1. CREATE TABLE WHOLELOTTARECORDS (
2. ID BIGINT NOT NULL PRIMARY KEY,
3. DESCRIPTION VARCHAR(32)
4. );
6. INSERT INTO MYBIGINTS VALUES (
7. -236453287458723,
8. 328832607832,
9. 22,
10. -56786237632476,
11. 0X6F55A09D42, -- 478177959234
12. 0X7FFFFFFFFFFFFFFF, -- 9223372036854775807
13. 0XFFFFFFFFFFFFFFFF, -- -1
14. 0X80000000, -- -2147483648, an INTEGER
15. 0X080000000, -- 2147483648, a BIGINT
16. 0XFFFFFFFF, -- -1, an INTEGER
17. 0X0FFFFFFFF -- 4294967295, a BIGINT
18. );
The hexadecimal INTEGERs in the above example are automatically cast to BIGINT before being inserted into the table. However, this happens after the numerical value is determined, so 0x80000000 (8 digits) and 0x080000000 (9 digits) will be saved as different BIGINT values.
